HY-TUGONGBUNonwoven Geotextile
General nonwoven for filtration and cushioning
- Key range
- 100-600 g/m²
- Width / roll
- 1-6 m
A high-strength woven grade for reinforcement of slopes, walls and embankment foundations where design tensile exceeds standard woven fabric.
PRODUCT / PHOTO
| Fibre | High-tenacity PP or PET yarn, woven |
| Mass per unit area | 150-500 g/m² |
| Width | 1-6 m |
| Tensile strength | ≥ 30-60 kN/m by grade |
| Elongation | ≤ 20% |
| Standard | Produced with reference to GB/T 17641 / GB/T 17640 |
Typical production ranges for Woven Reinforcement Geotextile; project values are confirmed against the drawing and test report before shipment.
Request data sheet & quoteHigh-strength reinforcement of slopes, walls and embankment foundations. The material package around Woven Reinforcement Geotextile — cushion geotextile, drainage, anchoring and welding — is selected with the same drawing.
Resin and surface type, standard range, roll form and the installation points that affect welding quality.
This grade is selected by design tensile, not by mass. If the specification calls for a geogrid, use a geogrid; a woven geotextile provides distributed tensile reinforcement but different interface behaviour.
Compare with my specificationLinyi tailings dam starter lining — 1.5 mm HDPE + 600 g/m² geotextile. Reference configuration for Woven Reinforcement Geotextile, not a delivered project record.
Reference configurations, not delivered project records.
A high-strength woven grade for reinforcement of slopes, walls and embankment foundations where design tensile exceeds standard woven fabric.
Final thickness, width and surface are confirmed against the drawing, design head and chemical exposure.
Welding parameters and seam records for Woven Reinforcement Geotextile are supplied with the shipment; for the first production welds, an engineer can attend site.
Not automatically. Both carry tensile load, but geogrids have apertures and interlock with fill. The design should state which reinforcement mechanism is required.
As a cushion under geomembrane, 500-600 g/m² is common; for drainage and filtration in normal earthworks 200-300 g/m² is usually sufficient. Check the design specification for tensile and permeability values.
Filament geotextile has higher tensile strength and better durability for reinforcement and heavy civil work. Staple fibre is cost-effective for filtration, separation and protection layers.
Yes. A 500-600 g/m² nonwoven geotextile is typically placed between the prepared subgrade and the geomembrane to prevent puncture and to provide drainage.
Other products in the geotextile range, plus the eight material systems used around Woven Reinforcement Geotextile.
HY-TUGONGBUGeneral nonwoven for filtration and cushioning
HY-CHANGSIHigh-strength filament geotextile
HY-DUANSICost-effective staple-fibre geotextile
HY-DILUNPolyester geotextile for chemical exposure
Fill what you know. The button creates a structured email in your mail app; nothing is stored on this website.
Send the specification values, area, head and delivery port for Woven Reinforcement Geotextile; we will confirm the standard and reply with a material schedule.